Agilent Liquid Chromatograph
More
Agilent Liquid Chromatograph
Agilent 1200 series unit system is for QA/QC application, as well as other demanded economical HPLC system with high performance applications.
Introduction:
Agilent LC 1200 liquid chromatograph
Product number: C40358
Origin: the United States
Product model: agilent 1200
Agilent 1200 series unit system for modular design, it is the ideal launch system can upgrade, completely can according to the need of future, extended system automation and detector performance or to add components, thus protecting your investment agilent 1200 series unit system have unparalleled durability, reliability, and many of the built-in efficient function, small box contains the most advanced hardware this fast and convenient maintenance of the system, users only need a little training can get a job, is the most worth it and use the system.
Application:
Agilent 1200 series four pumps are applicable to all need continuous method development, research, and the widely application of solvents choice, with maximum flexibility in choosing its solvent and automation.
Agilent 1200 quaternary system can be used in different solvents to quickly switch between methods, you can use the binary, ternary and quaternary gradient, is the most flexible system on the market.
And any agilent 1200 performance liquid chromatography (HPLC), after a series of combination of automatic sampler agilent 1200 performance liquid chromatography (HPLC) series of quaternary system is very suitable for many methods of high flux workflow.
20 times faster than conventional liquid chromatography, and with the same or better data quality (resolution), sensitivity, precision and high resolution increased by 60% compared with HPLC. With the same or better data quality (resolution, sensitivity, precision)
Delay volume can be configured, and is suitable for various applications. Can support the standard as well as support narrow diameter column column - suitable for RRLC and HPLC
Does not affect the compatibility of existing performance liquid chromatography (HPLC) method. Standard configuration delay volume (600-00 & micro; L), narrow pillar is most suited to support up to 300 mm diameter column on the LC/MS. Low latency volume configuration (120 & micro; L)
Regulations adaptability, in line with the most stringent regulations
Have a wide range of more than 70 kinds of RRHT column has extensive applicability
From liquid chromatography to RRLC can is simple, rapid and reliable method to transfer RRHT and liquid chromatography column with the same chemical properties of 2000 samples per day. High flux configuration, by alternating column regeneration (ACR) system consists of two pump, two pillar of chromatographic column and one for the alternate switch 2 ps / 10 pt valve.
"The basic system"
Rapid high liquid phase separation system
Binary liquid chromatography Four yuan liquid system
Unit performance liquid chromatography (HPLC)
Purification system
HPLC - Chip/MS system
NaLiu liquid chromatography system
Capillary liquid chromatography system
The 1200 series detector
Diode array detector SL
Diode array detector
Fluorescent column detector
Multiwavelength detector
Multiwavelength detector SL
Refractive index detector
Variable wavelength detector
Multiwavelength detector SL
Regulations adaptability, in line with the most stringent regulations
Have a wide range of more than 70 kinds of RRHT column has extensive applicability
Convenient to use four kinds of solvents, such as gradient or gradient analysis method is suitable for the rapid development and rapid equipped with mobile phase, and flush the HPLC system
Wide flow range and the highest velocity 10 mL/min, delay volume 00-1100 & micro; L, suitable for small diameter column, standard column and half preparation applications.
Through Instant Pilot chemical workstation or EZChrom software components or agilent, can be easily programmed and control.
Contains trace to take off the angry machine, vacuum degassing efficiency, realize the operation accessibility and highest performance, without the need for helium gas.
Direct the front rapid replacement of maintenance parts.
Through self diagnosis, built-in logging and testing methods, in the process of the programming to quickly determine the problem.
Early maintenance feedback (EMF) long-term continuous monitoring instrument use and user preset limit, once beyond the limit, will provide feedback.
Within the scope of all the agilent 1200 series of HPLC components can upgrade and extend.
Carefully build a new generation of Agilent 1200 performance liquid chromatography (HPLC) system, the chromatographic separation and analysis speed, detection sensitivity and samples to the perfect combination of flux; Modular design, suitable for their own applications require easier for users to obtain the ideal configuration.